Skip to content

Waste codes

D006: Cadmium

The toxicity characteristic code for cadmium. Regulatory level 1.0 mg/L by TCLP.

D006 is the RCRA waste code for waste that fails the toxicity characteristic for cadmium. A waste carries D006 when the Toxicity Characteristic Leaching Procedure extract contains 1.0 mg/L or more of cadmium.

Source: 40 CFR 261.24, Table 1

Where D006 waste comes from

The streams that most often carry D006 in Southeast industry:

  • Electroplating and metal finishing
  • Nickel cadmium battery manufacturing
  • Pigment production
  • Plastics stabilizers
  • Galvanizing operations

Electroplating wastewater sludge usually carries the F006 listing as well, which takes precedence for land disposal restrictions.

If you generate a cadmium bearing stream

The practical question is rarely whether cadmium is present. It is whether enough of it leaches out under the TCLP to cross 1.0 mg/L. Two plants running the same process can land on opposite sides of that line depending on the matrix the waste sits in, so the determination is made per stream rather than per industry.

That matters commercially as well as legally. A stream that passes is managed as non-hazardous at a fraction of the cost, and a stream that fails carries D006 from the moment it is generated, not from the moment it is tested. Where the result sits close to the threshold, it is worth retesting when the process changes.

If you are working with electroplating and metal finishing and have not characterized the waste, that is the place to start. Send what you have and a Certified Hazardous Materials Manager will tell you whether testing is needed or whether process knowledge already settles it.

How the determination is made

A generator must determine whether a waste is hazardous under 40 CFR 262.11. For D006 that means either testing by TCLP or applying knowledge of the process.

  • TCLP extraction under SW-846 Method 1311, analyzed for cadmium
  • Regulatory level for comparison: 1.0 mg/L
  • Process knowledge is acceptable where the input materials and process are documented
  • Testing settles the question. Guessing at a code is how a load gets rejected
  • The determination and its basis are retained for three years under 40 CFR 262.40

How D006 waste is treated

Stabilization, or high temperature metals recovery where the plating sludge concentration supports it

See hazardous waste disposal

Common questions

What is the regulatory level for D006?

1.0 mg/L of cadmium in the TCLP extract. At or above that concentration the waste carries D006 and is regulated as hazardous from the point of generation. The full table is at 40 CFR 261.24.

Does total cadmium content decide whether my waste is D006?

No. The toxicity characteristic is based on what leaches out under the TCLP, not on total concentration. A waste can hold a high total concentration and still pass, and the reverse is possible where the matrix releases readily.

Can D006 waste go straight to landfill?

Not untreated. Land disposal restrictions at 40 CFR Part 268 require the waste to meet a treatment standard before land disposal, and a land disposal restriction notification travels with every shipment.

Is D006 the only code my waste carries?

Often not. A stream can fail more than one characteristic and can also be listed. Every applicable code goes on the manifest, and the most stringent treatment standard governs how the waste is handled.

Who decides my waste is D006?

You do. The duty to determine sits with the generator under 40 CFR 262.11, not with the transporter or the receiving facility. Greer will characterize the stream and assign codes, but the determination remains yours to make and to document.

Related services

Not sure how this applies to your stream?

Send a profile, an old manifest, or photographs of the drums. A technical professional will tell you what you are holding.

This page summarizes federal requirements and is not legal advice. State programs can be more stringent than the federal baseline. Verify against current federal and state regulations before acting. Last reviewed September 2026.